Standard 10 sqmm 16sqmm 3 4 Core Pure Copper Core NYY Power Cables

The cable are mainly used for power distribution in power stations, industrial installation and switchgears, as well as in local mains.

Standard 10 sqmm 16sqmm 3 4 Core Pure Copper Core NYY Power Cables

The cable are mainly used for power distribution in power stations, industrial installation and switchgears, as well as in local mains.

Product Description

Application

The cable are mainly used for power distribution in power stations, industrial installation and switchgears, as well as in local mains. Able to bear certain traction during installation. For fixed installation underground, in interior premises, cable ducts, in the open air and in water if no risk of any mechanical damage is to be expected. Laying single core cable in magnetic ducts is not allowed.

 

Characteristics

Rated voltage: 0.6 / 1 kV

Maximum Conductor Temperature: under normal (90℃), emergency (130℃) or short circuit no more than 5s (250℃) conditions.

Min. Ambient Temp. 0℃, after installation and only when cable is in a fixed position

Min. Bending Radius: 20 x cable O.D for single core

15 x cable O.D for multi core

 

Construction

0.6-1KV Unarmored Copper Cable

① Conductor: Compact stranded copper conductor, Cl.2 as per IEC 60228

② Insulation: XLPE (cross-linked polyethylene) rated at 90 OC

③ Sheath: PVC or FR-PVC type ST2 to IEC 60502, black

 

Standards

International: IEC 60502, IEC 60228

China: GB/T 12706

Other standards such as BS, DIN and ICEA upon request

 

Certificates

CE, RoHS, CCC and more others at request

0.6-1KV Unarmored Copper Cable

Specifications

Single Core Power Cable

Nom. Cross-section of conductor

Insulation Thickness

Sheath Thickness

Approx. O.D.

Approx Weight

Max. D.C. Resistance of Conductor (20°C)

Test Voltage A.C

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In air(A)

In soil(A)

1×1.5

0.7

1.4

6

53

12.1

3.5

22

33

1×2.5

0.7

1.4

6

68

7.41

3.5

31

43

1×4

0.7

1.4

7

87

4.61

3.5

41

56

1×6

0.7

1.4

7

110

3.08

3.5

52

70

1×10

0.7

1.4

8

155

1.83

3.5

71

94

1×16

0.7

1.4

9

220

1.15

3.5

92

120

1×25

0.9

1.4

10

345

0.727

3.5

120

155

1×35

0.9

1.4

12

424

0.524

3.5

150

185

1×50

1

1.4

13

555

0.387

3.5

180

220

1×70

1.1

1.4

14

770

0.268

3.5

230

270

1×95

1.1

1.5

16

1040

0.193

3.5

285

320

1×120

1.2

1.5

18

1290

0.153

3.5

335

365

1×150

1.4

1.6

20

1590

0.124

3.5

385

410

1×185

1.6

1.6

22

1944

0.0991

3.5

450

465

1×240

1.7

1.7

25

2510

0.0754

3.5

535

540

1×300

1.8

1.8

27

3042

0.0601

3.5

620

610

1×400

2

1.9

31

3869

0.047

3.5

720

695

1×500

2.2

2.1

35

4910

0.0366

3.5

835

780

1×630

2.4

2.2

40

6220

0.0283

3.5

960

880

1×800

2.6

2.4

45

7870

0.0221

3.5

1110

970

1×1000

2.8

2.6

51

9804

0.0176

3.5

1230

1060

 

2 Cores Power Cable

Nom. Cross-section of conductor

Insulation Thickness

Sheath Thickness

Approx. O.D.

Approx Weight

Max. D.C. Resistance of Conductor (20°C)

Test Voltage A.C

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In air(A)

In soil(A)

2×2.5

0.7

1.8

11.8

151

7.41

3.5

26

35

2×4

0.7

1.8

12.7

198

4.61

3.5

34

45

2×6

0.7

1.8

13.7

250

3.08

3.5

43

57

2×10

0.7

1.8

15

374

1.83

3.5

60

77

2×16

0.7

1.8

17

518

1.15

3.5

83

105

2×25

0.9

1.8

20

772

0.727

3.5

105

125

2×35

0.9

1.8

22

1006

0.524

3.5

125

155

2×50

1

1.8

20

1365

0.387

3.5

160

185

2×70

1.1

1.8

21

1872

0.268

3.5

200

225

2×95

1.1

1.8

24

2475

0.193

3.5

245

270

2×120

1.2

1.8

27

3089

0.153

3.5

285

310

2×150

1.4

1.9

30

3834

0.124

3.5

325

345

 

3 Cores Power Cable

Nom. Cross-section of conductor

Insulation Thickness

Sheath Thickness

Approx. O.D.

Approx Weight

Max. D.C. Resistance of Conductor (20°C)

Test Voltage A.C

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In air(A)

In soil(A)

3×1.5

0.7

1.5

10

145

12.1

3.5

20

27

3×2.5

0.7

1.5

11

185

7.41

3.5

26

35

3×4

0.7

1.5

12

250

4.61

3.5

34

45

3×6

0.7

1.5

13

320

3.08

3.5

43

57

3×10

0.7

1.8

16

450

1.83

3.5

60

77

3×16

0.7

1.8

18

640

1.15

3.5

83

105

3×25

0.9

1.8

21

940

0.727

3.5

105

125

3×35

0.9

1.8

23

1260

0.524

3.5

125

155

3×50

1

1.8

23

1670

0.387

3.5

160

185

3×70

1.1

1.8

26

2280

0.268

3.5

200

225

3×95

1.1

1.9

30

3020

0.193

3.5

245

270

3×120

1.2

2

32

3790

0.153

3.5

285

310

3×150

1.4

2.2

37

4750

0.124

3.5

325

345

3×185

1.6

2.3

41

5654

0.0991

3.5

375

390

3×240

1.7

2.4

46

7243

0.0754

3.5

440

450

3×300

1.8

2.6

51

9465

0.0601

3.5

505

515

3×400

2

3

64

12066

0.047

3.5

570

575

 

4 Cores Power Cable

Nom. Cross-section of conductor

Insulation Thickness

Sheath Thickness

Approx. O.D.

Approx Weight

Max. D.C. Resistance of Conductor (20°C)

Test Voltage A.C

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In air(A)

In soil(A)

4×4

0.7

1.8

13

253

4.61

3.5

34

45

4×6

0.7

1.8

14

337

3.08

3.5

43

57

4×10

0.7

1.8

17

501

1.83

3.5

60

77

4×16

0.7

1.8

20

778

1.15

3.5

83

105

4×25

0.9

1.8

23

1160

0.727

3.5

105

125

4×35

0.9

1.8

25

1554

0.524

3.5

125

155

4×50

1

1.8

23

2148

0.387

3.5

160

185

4×70

1.1

1.8

27

2928

0.268

3.5

200

225

4×95

1.1

1.9

31

3854

0.193

3.5

245

270

4×120

1.2

2

33

4925

0.153

3.5

285

310

4×150

1.4

2.2

38

6238

0.124

3.5

325

345

4×185

1.6

2.3

42

7562

0.0991

3.5

375

390

4×240

1.7

2.5

47

9836

0.0754

3.5

440

450

4×300

1.8

2.6

52

12550

0.0601

3.5

505

515

4×400

2

3.1

66

15929

0.047

3.5

570

575

 

5 Cores Power Cable

Nom. Cross-section of conductor

Insulation Thickness

Sheath Thickness

Approx. O.D.

Approx Weight

Max. D.C. Resistance of Conductor (20°C)

Test Voltage A.C

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In air(A)

In soil(A)

5×4

0.7

1.8

14.5

349

4.61

3.5

34

45

5×6

0.7

1.8

15.8

460

3.08

3.5

43

57

5×10

0.7

1.8

19

699

1.83

3.5

60

77

5×16

0.7

1.8

22

1013

1.15

3.5

83

105

5×25

0.9

1.8

25

1566

0.727

3.5

105

125

5×35

0.9

1.9

28

2083

0.524

3.5

125

155

5×50

1

2

31

2921

0.387

3.5

160

185

5×70

1.1

2.1

36

3974

0.268

3.5

200

225

5×95

1.1

2.2

39

5297

0.193

3.5

245

270

5×120

1.2

2.4

44

6638

0.153

3.5

285

310

5×150

1.4

2.5

49

8290

0.124

3.5

325

345

5×185

1.6

2.7

55

10215

0.0991

3.5

375

390

5×240

1.7

3

64

13130

0.0754

3.5

440

450

5×300

1.8

3.2

70

16670

0.0601

3.5

505

515

 

 3+1 Cores Power Cable

Nom. Cross-section of conductor

Insulation Thickness

Sheath Thickness

Approx. O.D.

Approx Weight

Max. D.C. Resistance of Conductor (20°C)

Test Voltage A.C

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In air(A)

In soil(A)

3×4+1×2.5

0.7

1.8

13

236

4.61

3.5

34

45

3×6+1×4

0.7

1.8

14

316

3.08

3.5

43

57

3×10+1×6

0.7

1.8

17

461

1.83

3.5

60

77

3×16+1×10

0.7

1.8

19

679

1.15

3.5

83

105

3×25+1×16

0.9

1.8

22

1065

0.727

3.5

105

125

3×35+1×16

0.9

1.8

24

1360

0.524

3.5

125

155

3×50+1×25

1

1.8

25

1901

0.387

3.5

160

185

3×70+1×35

1.1

1.9

28

2585

0.268

3.5

200

225

3×95+1×50

1.1

2

32

3518

0.193

3.5

245

270

3×120+1×70

1.2

2.1

35

4443

0.153

3.5

285

310

3×150+1×70

1.4

2.2

40

5326

0.124

3.5

325

345

3×185+1×95

1.6

2.4

43

8501

0.0991

3.5

375

390

3×240+1×120

1.7

2.5

48

11155

0.0754

3.5

440

450

3×300+1×150

1.8

2.7

54

14470

0.0601

3.5

505

515

3×400+1×240

2

3.1

66

309

0.047

3.5

570

575

 

3+2 Cores Power Cable

Nom. Cross-section of conductor

Insulation Thickness

Sheath Thickness

Approx. O.D.

Approx Weight

Max. D.C. Resistance of Conductor (20°C)

Test Voltage A.C

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In air(A)

In soil(A)

3×4+2×2.5

0.7

1.8

13.9

413

4.61

3.5

34

45

3×6+2×4

0.7

1.8

15.3

6682

3.08

3.5

43

57

3×10+2×6

0.7

1.8

18

603

1.83

3.5

60

77

3×16+2×10

0.7

1.8

21

888

1.15

3.5

83

105

3×25+2×16

0.9

1.8

24

1342

0.727

3.5

105

125

3×35+2×16

0.9

1.8

26

1647

0.524

3.5

125

155

3×50+2×35

1

1.9

29

2386

0.387

3.5

160

185

3×70+2×35

1.1

2.0

32

3201

0.268

3.5

200

225

3×95+2×50

1.1

2.1

36

4269

0.193

3.5

245

270

3×120+2×70

1.2

2.3

41

5437

0.153

3.5

285

310

3×150+2×70

1.4

2.4

44

6519

0.124

3.5

325

345

3×185+2×95

1.6

2.5

49

8101

0.0991

3.5

375

390

3×240+2×120

1.7

2.7

54

10340

0.0754

3.5

440

450

3×300+2×150

1.8

2.8

56

12810

0.0601

3.5

505

515

 

4+1 Cores Power Cable

Nom. Cross-section of conductor

Insulation Thickness

Sheath Thickness

Approx. O.D.

Approx Weight

Max. D.C. Resistance of Conductor (20°C)

Test Voltage A.C

Current Rating

mm2

mm

mm

mm

kg/km

Ω/km

kV/5min

In air(A)

In soil(A)

4×4+1×2.5

0.7

1.8

14.5

331

4.61

3.5

34

45

4×6+1×4

0.7

1.8

15.9

435

3.08

3.5

43

57

4×10+1×6

0.7

1.8

18

649

1.83

3.5

60

77

4×16+1×10

0.7

1.8

21

965

1.15

3.5

83

105

4×25+1×16

0.9

1.8

25

1456

0.727

3.5

105

125

4×35+1×16

0.9

1.8

27

1863

0.524

3.5

125

155

4×50+1×25

1

1.9

29

2633

0.387

3.5

160

185

4×70+1×35

1.1

2.0

32

3565

0.268

3.5

200

225

4×95+1×50

1.1

2.1

36

4735

0.193

3.5

245

270

4×120+1×70

1.2

2.3

41

5977

0.153

3.5

285

310

4×150+1×70

1.4

2.4

44

7276

0.124

3.5

325

345

4×185+1×95

1.6

2.5

49

9055

0.0991

3.5

375

390

4×240+1×120

1.7

2.7

54

11567

0.0754

3.5

440

450

4×300+1×150

1.8

3.1

66

14321

0.0601

3.5

505

515

Request a Quote

  • wechat

    Janey: +86 138 3311 9023

  • wechat

    Ivy: +86 150 8117 8223

  • wechat

    Chloe: +86 181 3119 7232

Chat with Us